The AiP4056 is a single-cell Li-ion battery charger with thermal regulation that adopts trickle/constant
current/constant voltage charging mode. The charging voltage is set at 4.2V, and the charging current can
be set through external resistors. When the battery voltage reaches the set value and charging current drops
to 1/10 of set value, AiP4056 automatically terminates charging and enters standby mode. When the power
supply is removed, the AiP4056 automatically enters low power standby state
Operating Temperature(℃) :
-40~85VIin(Min)(V) :
4.25Vin(Max)(V) :
5.5Battery Voltage :
4.2V±1%Programmable Current(A) :
0.5Standby Current (Typ)(uA) :
150Package :
SOT23-5The maximum charging current: 1A
Trickle/constant current/constant voltage charging mode
Pre-charge voltage: 4.2V±1%
C/10 charge termination
Power current in the standby mode: 70uA
2.9V trickle current charging
Charging state dual output, no battery and fault state display
Overtemperature protection for charging
BAT reverse connection protection
Battery temperature monitoring
Package form: ESOP8/DFN8